Back

Fontan Circulation Failure

Also known as: Failing Fontan

Fontan circulation failure is the progressive loss of the ability of a Fontan circulation to deliver adequate cardiac output at an acceptable venous pressure. Systemic venous blood reaches the lungs passively, with no subpulmonary ventricle, so any rise in resistance or fall in ventricular performance is poorly tolerated.

Survivors of Fontan completion are a large and ageing population. Transplant free survival is roughly 85% at 20 years and 70 to 75% at 30 years in large series, and failure becomes frequent after the second decade.

Causes are ventricular systolic or diastolic dysfunction (earlier and more often with a systemic right ventricle), atrioventricular valve regurgitation, atrial tachyarrhythmia, sinus node dysfunction, raised pulmonary vascular resistance, obstruction of the conduit or branch pulmonary arteries, venovenous and aortopulmonary collaterals, thrombus, and chronotropic incompetence.

Two phenotypes occur. Failure with reduced ejection fraction responds partly to heart failure drugs. Failure with preserved ejection fraction is commoner, shows high venous pressure, low output and lymphatic failure, and responds poorly to them.

Complications are protein losing enteropathy (up to about 10 to 15% in long term series), plastic bronchitis (1 to 5%), liver fibrosis and cirrhosis, renal dysfunction, thromboembolism, cachexia and sudden death.

Pathophysiology.

Cardiac output depends on the pressure gradient from systemic veins to the left atrium, on pulmonary vascular resistance, on ventricular filling and on rhythm. Central venous pressure in a stable Fontan is about 10 to 14 mmHg, which leaves little reserve.

Chronic venous hypertension and low output congest the liver and gut, raise lymphatic pressure and reduce renal perfusion. Protein loss through the gut and cast formation in the airways are expressions of lymphatic failure.

Absent pulsatile pulmonary flow lowers nitric oxide production, and the pulmonary vascular bed remodels over time. Skeletal muscle wasting reduces the peripheral pump and exercise capacity.

Loss of sinus rhythm causes a sharp fall in output because atrial contraction contributes to ventricular filling and pulmonary flow.

Related

Clinical toolsCalculators

Latest content

Atlas’ Videos

Growing

More conditions, continuously.

Entries are added and revised from the newsroom rather than shipped in versions. If something reads out of date, it can be corrected the same day.

Learn it.
Know it.
Own it.