Crossmatch and Antibody Screen
The antibody screen and crossmatch are the last laboratory safeguards before red cell transfusion.
The antibody screen uses the indirect antiglobulin technique to detect red cell alloantibodies in the recipient's plasma, with group O reagent cells of known antigen profile. The crossmatch tests the recipient's plasma against the red cells of the unit chosen, to confirm ABO compatibility and to exclude an antibody against an antigen carried by the donor cells.
Together with the ABO and RhD group, they decide which units are safe and how quickly they can be issued.
Clinically significant antibodies, those reactive at 37 °C or in the antiglobulin phase, are found in about 1 to 3% of hospital patients, and more often after multiple transfusions, pregnancies or transplantation. Most transfusion laboratories now issue blood electronically to patients with a negative screen and a verified group history, and keep serological crossmatching for the rest.
Indications. Any planned or likely red cell transfusion, pregnancy at booking and during gestation, surgery with a risk of major blood loss, regular transfusion in sickle cell disease or thalassaemia, transplantation, suspected transfusion reaction, and before and during anti-CD38 therapy.
Specimen. EDTA or clotted venous blood, labelled at the bedside with full patient identifiers. A sample is valid for 3 days when the patient has been transfused or pregnant in the previous 3 months (day of collection is day 0), and for up to 7 days otherwise, depending on local policy. A second independent sample, or a documented historical group, is needed before group specific red cells are issued.