Multifocal Atrial Tachycardia
Also known as: MAT
Multifocal atrial tachycardia (MAT) is an irregular atrial rhythm at a rate over 100/min with at least three different P wave morphologies in the same lead, variable PP, PR and RR intervals, an isoelectric baseline between P waves, and no single dominant atrial pacemaker.
When the rate is under 100/min the rhythm is called a wandering atrial pacemaker. It is found in 0.05 to 0.3% of hospital ECGs, mostly in people over 60 years. Between 60 and 80% have chronic lung disease, especially chronic obstructive pulmonary disease with hypoxaemia and hypercapnia.
Other causes are pulmonary hypertension, pulmonary embolism, sepsis, heart failure, coronary disease, valve disease, hypomagnesaemia, hypokalaemia, theophylline toxicity, beta agonist excess and postoperative states. In hospital mortality is high (30 to 60%) because of the underlying illness and not the rhythm.
A substantial share of patients later develop atrial fibrillation.
Pathophysiology. Triggered activity from raised intracellular calcium and delayed afterdepolarisations, promoted by hypoxia, hypercapnia, acidosis, catecholamines, methylxanthines, electrolyte depletion and atrial stretch from raised right atrial pressure. Several atrial foci fire in turn, giving the irregular rhythm.