Structural Valve Deterioration
Also known as: SVD
Structural valve deterioration is intrinsic, permanent degeneration of a bioprosthetic valve (surgical or transcatheter) that causes stenosis, regurgitation or both. It is the main limit to bioprosthesis durability and the commonest reason for reintervention.
Deterioration is defined by morphological change (leaflet thickening, calcification, tear, flail, or stent or frame fracture) and by haemodynamic change from the early post-implantation baseline.
Haemodynamic deterioration is staged as:
- moderate: increase in mean gradient of 10 mmHg or more to a mean gradient of 20 mmHg or more, or new moderate regurgitation
- severe: increase in mean gradient of 20 mmHg or more to a mean gradient of 30 mmHg or more, or new severe regurgitation
Surgical bioprostheses usually last 10 to 15 years, with failure becoming frequent after 10 years. Durability is shorter in younger patients (deterioration is fastest under age 40 to 50), in the mitral position and with chronic kidney disease. Transcatheter valve durability is less well defined beyond 8 to 10 years.
Risk factors are young age, mitral position, patient prosthesis mismatch, chronic kidney disease and dialysis, hyperparathyroidism, hypercalcaemia, diabetes and metabolic syndrome, hypertension, and pregnancy.
Pathophysiology.
Calcification of the leaflets is driven by lipid and calcium deposition, glutaraldehyde fixed tissue, and inflammation. Collagen fibres degrade from mechanical stress, which causes tears, perforation and cuspal prolapse.
Immune responses to residual xenoantigens and high pressure stress on the leaflets add to damage. Younger patients with higher blood pressure and metabolic activity deteriorate faster.
Deterioration must be distinguished from non-structural failure (thrombosis, pannus, endocarditis, paravalvular leak, mismatch), which has different treatment.