Patient prosthesis mismatch (PPM) is present when the effective orifice area of a normally functioning prosthetic valve is too small for the size of the patient, so that gradients are higher than expected and flow is obstructed.

It is quantified by the indexed effective orifice area (iEOA), which is the effective orifice area divided by body surface area. In the aortic position, with BMI under 30 kg/m2, moderate PPM is an iEOA of 0.85 to 0.66 cm2/m2 and severe PPM is 0.65 cm2/m2 or less.

With BMI of 30 kg/m2 or more, moderate PPM is 0.70 to 0.56 cm2/m2 and severe is 0.55 cm2/m2 or less. In the mitral position, moderate PPM is an iEOA of 1.2 to 0.9 cm2/m2 and severe is under 0.9 cm2/m2.

Moderate aortic PPM follows about 20 to 70% of surgical valve replacements (depending on the definition) and severe PPM about 2 to 20%. After transcatheter implantation severe PPM is less frequent in the aortic position, although it occurs.

Pathophysiology. A fixed small orifice raises the pressure gradient, which rises with the square of flow, so gradients climb with exercise and high output states. Pressure overload slows regression of left ventricular hypertrophy, limits exercise capacity and coronary flow reserve, and promotes ventricular remodelling.

In the mitral position it raises left atrial pressure and pulmonary pressure and favours atrial fibrillation. Severe PPM is linked to heart failure, earlier structural valve degeneration, and higher mortality, especially in patients under 70 years or with ejection fraction under 50%.