Failed Vacuum Delivery

Failed vacuum delivery is failure to deliver with a vacuum cup after 3 pulls with no descent, 2 cup detachments, or 20 minutes of application. It results from an incorrect cup position, poor traction direction, an occiput posterior or transverse head, disproportion, a large caput or poor expulsive effort. It matters because persistence causes scalp injury, subgaleal haemorrhage and intracranial haemorrhage, and caesarean section is then needed.

  • Risk factors: occiput posterior position, station above +2, large baby, obesity, maternal exhaustion, preterm baby (below 34 weeks vacuum is avoided).
  • Vacuum is not used for face or brow presentation, bleeding disorders in the fetus, or before 34 weeks.
  • A well positioned flexion point cup improves success.