MR Angiography
MR angiography is a family of MRI techniques that show blood vessels without ionising radiation or iodinated contrast. It images arteries in the head, neck, chest, abdomen, pelvis and limbs.
There are two main approaches. Contrast enhanced MR angiography uses an intravenous gadolinium bolus (0.1 mmol each kg, often 0.05 to 0.1) and a fast 3D gradient echo sequence timed to the arterial phase, with coverage from the aortic arch to the feet using a moving table.
Non-contrast techniques use the flow of blood itself: time-of-flight (inflow of unsaturated spins, the usual choice for the intracranial arteries), phase contrast (velocity encoded), and balanced steady state free precession or quiescent interval slice selective methods for the limbs and the thorax.
Slices are 0.8 to 1.5 mm thick, with a large field of view for body imaging. The images are reformatted using maximum intensity projection, multiplanar reformats and volume rendering. The examination takes 20 to 45 minutes.
Peripheral arterial disease affects about 5 to 10% of people over 55, cerebrovascular disease causes about 11% of deaths worldwide, and aortic disease is a leading cause of sudden death in older adults.
MR angiography has a sensitivity and specificity of 90 to 98% for significant carotid, renal and peripheral artery stenosis compared with catheter angiography.
It is the preferred test for patients with allergy to iodinated contrast, renal impairment (non-contrast methods), young patients who need repeated follow up, and complex congenital vascular anomalies.
Indications.
- Intracranial: aneurysm screening and follow up, stenosis, occlusion, dissection, vasculitis, moyamoya, and vascular malformations.
- Neck: carotid and vertebral stenosis, dissection, fibromuscular dysplasia and arterial anomalies.
- Thoracic aorta: aneurysm, dissection, coarctation, aortitis (Takayasu), congenital anomalies and follow up after repair.
- Abdominal aorta and branches: aneurysm, mesenteric ischaemia, renal artery stenosis, and visceral aneurysm.
- Peripheral arteries: claudication, critical limb ischaemia, aneurysm and pre-operative bypass planning.
- Pulmonary arteries: congenital anomalies, pulmonary hypertension, sequestration and stenosis.
- Vascular malformations and tumours: mapping of arteriovenous malformations and vascular tumours.
- Pre-operative planning: transplant donors, flap surgery.
- Follow up of stents, grafts and endovascular repair when CT is not appropriate.
- Patients who need repeat angiography and should avoid radiation.
Not for emergencies where CT angiography is faster, for patients with unstable haemodynamics, or for assessment of calcification and stent lumen, where CT is better.
Contraindications and precautions.
- The usual MRI safety screen. Many aneurysm clips, stents and coils are conditional. Metal in the field causes signal loss.
- Gadolinium: avoid in severe renal impairment (estimated glomerular filtration rate under 30 mL each minute) with linear agents. Macrocyclic agents, lowest dose, or non-contrast techniques are used.
- Pregnancy: non-contrast MR angiography only.
- Claustrophobia, inability to stay still or hold the breath.
- Severe arrhythmia degrades non-contrast gated techniques.
- Previous reaction to a gadolinium agent.
Preparation and technique.
No fasting is needed for most studies. A cannula is placed in an antecubital vein for contrast enhanced studies. Gating with the electrocardiogram or pulse is used for non-contrast limb and thoracic techniques.
For time-of-flight intracranial angiography, a 3D multi-slab sequence covers the circle of Willis without contrast, in about 5 to 8 minutes. For the neck, a 2D or 3D time-of-flight or contrast enhanced sequence covers from the aortic arch to the circle of Willis.
For body contrast enhanced studies, a test bolus or bolus tracking sets the delay, and the 3D acquisition is taken in a breath hold of 10 to 20 seconds. Multi-station peripheral studies use moving table or hybrid sequences, with a fast bolus chase and sometimes calf compression to delay venous return.
Subtraction of the pre-contrast mask reduces background. Delayed phases show slow flow and endoleaks.