MRI Knee
MRI of the knee is the best test for the menisci, cruciate and collateral ligaments, articular cartilage, bone marrow and synovium. It is a non-invasive alternative to diagnostic arthroscopy and avoids unnecessary operations.
The study uses a 1.5 or 3 tesla scanner with a dedicated knee coil. The knee is slightly flexed (about 5 to 10 degrees) and held still. Slices are 3 to 4 mm thick. The examination takes 15 to 30 minutes.
The core sequences are proton density or T2-weighted fast spin echo with fat suppression in sagittal, coronal and axial planes, and T1-weighted images in the sagittal or coronal plane. Three dimensional isotropic sequences allow reformatting. Cartilage specific sequences and compositional mapping are used in some centres.
Contrast is given only for synovitis, infection, tumour or after surgery (as a direct arthrogram when a graft or meniscal repair needs assessment).
Knee pain accounts for a large share of musculoskeletal consultations. Meniscal tears are found in over 30% of adults over 50, and most are degenerative and symptom free.
MRI has a sensitivity and specificity of over 90% for medial meniscal tears and cruciate ligament rupture, and a negative study has a high negative predictive value.
Indications.
- Acute injury with a locked knee, haemarthrosis, instability or suspected ligament rupture.
- Suspected meniscal tear with mechanical symptoms (locking, catching) after failed conservative treatment.
- Suspected cruciate or collateral ligament injury, and multiligament or dislocation injuries.
- Patellar dislocation and instability, and extensor mechanism injury.
- Occult fracture, stress fracture and bone bruise when radiographs are normal.
- Osteochondral lesions, osteonecrosis and cartilage defects.
- Septic arthritis, osteomyelitis and soft tissue infection.
- Inflammatory arthritis, synovitis and crystal disease.
- Bone and soft tissue tumours, popliteal cysts and masses.
- Painful arthroplasty or ligament reconstruction, and assessment before surgery.
- Children with knee pain, growth plate injury and osteochondritis.
Not indicated for classic osteoarthritis with typical radiographs, or for uncomplicated knee pain under 6 weeks without red flags.
Contraindications and precautions.
- The usual MRI safety screen. Most orthopaedic implants are safe, but metal causes artefact.
- Gadolinium: renal precautions apply.
- Claustrophobia: knee studies are done feet first in most scanners, which helps.
- Pregnancy: non-contrast knee MRI is acceptable.
- Large body size may limit coil fit.
Preparation and technique.
No preparation is needed. The patient lies supine with the knee in the coil, slightly flexed, and the foot is fixed to reduce motion.
Sagittal, coronal and axial fat suppressed proton density images are taken, with a T1 sequence for marrow. Thin 3D images may be added for cartilage and menisci.
Metal artefact reduction sequences are used after arthroplasty or fixation. Slices are angled along the cruciate ligaments when needed.